Call
800.835.2838
or
316.263.9511
By Part Number
By Keyword
Home
Products
About Us
Contact Us
Request Information
Adhesives & Sealants for Aerospace, Automotive & Industrial Applications
Air Valves for MMO (Marine, Mobile & Oil Field)
Industrial Air Valves Couplings & Manifolds
Pneumatic/Hydraulic Fittings & Couplings
Fluid Power Process Instrumentation & Process Control Equipment
All Categories
>
Drilling Rig Air Valves for MMO (Marine, Mobile & Oil Field)
>
Emerson Aventics (WABCO) Drilling Rig Air Valves
>
Aventics PowerMaster® Valve, 4-Way Directional Control
>
Rexroth PowerMaster® Double Solenoid Tapped Exhaust Valves (4 Way, 2 & 3 Position - 1/4" - 3/4" NPTF)
>
Item # item-10224
Download PDF
Download PDF
Printable Page
Email This Page
Save To Favorites
Please wait…
Item # item-10224, Rexroth PowerMaster® Double Solenoid Tapped Exhaust Valves (4 Way, 2 & 3 Position - 1/4" - 3/4" NPTF)
4 Way / 2 & 3 Position 1/4" - 1-1/4" NPTF Solenoid, Air Pilot & Mechanical Operators
TECHNICAL DATA:
Port Sizes:
1/4", 3/8", 1/2", 3/4", 1", 1-1/4" NPTF
Working Pressure:
Maximum valve inlet air pressure: 150 psi (10.3 bar)
Minimum air pilot pressure: 15 psi (1.0 bar) w/o return spring (all sizes)
30 psi (2.1 bar) 1" and 1-1/4" valves w/return spring
40 psi (2.8 bar) 1/2" and 3/4" valves w/return spring
50 psi (3.4 bar) 1/4" and 3/8" valves w/return spring
Valves can also be used for vacuum or dual pressure service when externally piloted.
Flow:
C
v
2.39 (2390 Nl/min) 1/4" NPTF
C
v
3.73 (3730 Nl/min) 3/8" NPTF
C
v
6.17 (6170 Nl/min) 1/2" NPTF
C
v
7.88 (7880 Nl/min) 3/4" NPTF
C
v
13.61 (13,610 Nl/min) 1" NPTF
C
v
15.75 (15,750 Nl/min) 1-1/4" NPTF
Temperature Range:
-20ºF to +160ºF (-29ºC to 71ºC)
Media:
Air and inert gases (In service higher than 18 cycles per minute or with continuous air flow, a lubricator is recommended.)
Materials:
Bodies and operators: Die cast aluminum
Spool: Machined from high-tensile aluminum, hard anodized, ground & polished to 8 micro-inch finish
Seals: Buna-N, oil-resistant, and bonded to a metallic ring (Hl-Nitrile Buna-N seals are also available.
Manual Override:
Non-Locking
Note:
Other coil voltages are available - selection will be done at checkout.
larger image
larger image
Specifications
·
Dimensions
·
Electrical Data
·
Features
Specifications
Model No.
PT 024115-8484
PT 24115-8484
PT-024115-08484
PT024115-8484
PT24115-8484
Pilot
External Air Pilot
Port Size
1/4
in.
Type
Center Spring - 3 Pos. Closed Center
Coil Voltage
12 VDC
24 VDC
110 VAC@50 Hz
120 VAC@60 Hz
220 VAC@50 Hz
240 VAC@60 Hz
240 VDC
480 VAC@60 Hz
Dimensions
A
1/4
in.
3/8
in.
B
1.50
in.
38
mm
C
2.56
in.
65
mm
D
2.56
in.
65
mm
E
6.91
in.
176
mm
F
1.00
in.
25
mm
G
2.00
in.
51
mm
H
0.69
in.
18
mm
I
1.81
in.
48
mm
J
0.28
in.
7
mm
K
0.50
in.
13
mm
L
1.12
in.
28
mm
M
1.06
in.
27
mm
N
1.58
in.
40
mm
O
5.25
in.
133
mm
P
3.31
in.
84
mm
Q
4.38
in.
111
mm
R
1.58
in.
40
mm
S
1.50
in.
38
mm
T
3.00
in.
76
mm
Electrical Data
Standard Voltage
(all coils are rated for continues duty)
Power Consumption
Inrush
Holding
120, 240 VAC 60 Hz
33 VA
22 VA
12, 24 VDC
12 W
Features
Response time.
Actual test data shows only 175 milliseconds is required to fill a 250 cubic inch volume to 80% of line pressure with a normally closed solenoid operated valve. Where a spring is used to open the valve (normally open valve) only 253 milliseconds is required to fill the same volume.
Continuous-duty solenoid.
Won’t burn out...even when energized for extended periods. Pilot operated for fast response.
Lightweight aluminum spool
of extra large diameter assures high-speed performance. Requires only short movement to deliver high-capacity air flow. File-hard anodized surface, polished to an 8 micro-inch finish, withstands wear and abrasion; offers greatest sealing qualities, minimum friction and maximum speed. Spool is balanced so air pressure won’t affect its position.
Low-friction, positive sealing ring
is actually two seals in one; an outer static seal and an inner dynamic seal bonded to a metallic spacer ring. The ring protects the inner seal from the radical compression absorbed by the other seal. Assures longest life with positive sealing.
Seal retainers
keep inner and outer sealing surfaces in precise position for maximum reliability and efficiency. Combined with the non-compressible seal rings, Power- Master valve retainers eliminate tolerance build-up in the free stack height of both retainers and seals.
Free-floating piston
with extra large surface area means faster response at lower pressures.
Manual non-locking overrides
allow supplementary manual control an permits operating the valve when the electric power is off.
External pilot
allows an independent air supply to be connected to the pilot port in the valve operator or subplate for air pilot pressure.
Wire leads
of 24" allows simplified conduit wiring.
Solenoid coil removal.
Unscrew hex nut and slip off the solenoid housing and coil.
Exhaust restrictors
can be used in either or both exhaust port to provide speed control of cylinders. (Refer to Accessory Valve catalog SC-400.)
Powermaster Repair Kits
Aventics PowerMaster® Repair Kits
Site created by
ThomasNet Web Solutions
and powered by
Navigator Platform