Call 800.835.2838 or 316.263.9511Email
Distributor to Industry, Inc.
All Categories > Drilling Rig Air Valves for MMO (Marine, Mobile & Oil Field) > Emerson Aventics (WABCO) Drilling Rig Air Valves > Aventics PowerMaster® Valve, 4-Way Directional Control > Rexroth PowerMaster® Double Solenoid Tapped Exhaust Valves (1" & 1-1/4" NPTF) > Item # R431008611  
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Item # R431008611, Rexroth PowerMaster® Double Solenoid Tapped Exhaust Valves (1" & 1-1/4" NPTF)



4 Way / 2 & 3 Position 1/4" - 1-1/4" NPTF Solenoid, Air Pilot & Mechanical Operators

TECHNICAL DATA:
Port Sizes: 1/4", 3/8", 1/2", 3/4", 1", 1-1/4" NPTF
Working Pressure:
    Maximum valve inlet air pressure: 150 psi (10.3 bar)
    Minimum air pilot pressure: 15 psi (1.0 bar) w/o return spring (all sizes)
    30 psi (2.1 bar) 1" and 1-1/4" valves w/return spring
    40 psi (2.8 bar) 1/2" and 3/4" valves w/return spring
    50 psi (3.4 bar) 1/4" and 3/8" valves w/return spring
    Valves can also be used for vacuum or dual pressure service when externally piloted.
Flow:
    Cv 2.39 (2390 Nl/min) 1/4" NPTF
    Cv 3.73 (3730 Nl/min) 3/8" NPTF
    Cv 6.17 (6170 Nl/min) 1/2" NPTF
    Cv 7.88 (7880 Nl/min) 3/4" NPTF
    Cv 13.61 (13,610 Nl/min) 1" NPTF
    Cv 15.75 (15,750 Nl/min) 1-1/4" NPTF
Temperature Range: -20ºF to +160ºF (-29ºC to 71ºC)
Media: Air and inert gases (In service higher than 18 cycles per minute or with continuous air flow, a lubricator is recommended.)
Materials:
    Bodies and operators: Die cast aluminum
    Spool: Machined from high-tensile aluminum, hard anodized, ground & polished to 8 micro-inch finish
    Seals: Buna-N, oil-resistant, and bonded to a metallic ring (Hl-Nitrile Buna-N seals are also available.
Manual Override: Non-Locking

Note: Other coil voltages are available - selection will be done at checkout.





Specifications  · Dimensions  · Electrical Data  · Features  · Notes

Specifications

Model No.

PT 084107-3030
PT 84107-3030

PT-084107-03030

PT084107-3030

PT84107-3030

Type

No Springs

Pilot

Internal Air Pilot

Port Size

1 in.

Approx. Weight

12.25 lb
5.57
kg

Coil Voltage

24 VDC
120 VAC (Standard)


Dimensions

A

11 1/2 in.

B

16.25 in.
413
mm

C

4.13 in.
105
mm

D

2.59 in.
66
mm

E

4.38 in.
111
mm

F

4.19 in.
106
mm

G

2.75 in.
75
mm

H

1.31 in.
33
mm

J

2.88 in.
68
mm

K

2.63 in.
67
mm

L

2.88 in.
73
mm

M

2.13 in.
54
mm

N

1.31 in.
33
mm

O

1.50 in.
38
mm

P

0.34 in.
8.7
mm

Q

0.63 in.
15.9
mm

R

4.06 in.
103
mm

S

2.63 in.
67
mm

T

2.19 in.
56
mm

U

2.06 in.
52
mm

V

3.00 in.
76
mm


Electrical Data
Standard Voltage
(all coils are rated for continues duty)
Power Consumption
Inrush Holding
120, 240 VAC 60 Hz 33 VA 22 VA
12, 24 VDC 12 W




Features
  • Response time. Actual test data shows only 175 milliseconds is required to fill a 250 cubic inch volume to 80% of line pressure with a normally closed solenoid operated valve. Where a spring is used to open the valve (normally open valve) only 253 milliseconds is required to fill the same volume.
  • Continuous-duty solenoid. Won’t burn out...even when energized for extended periods. Pilot operated for fast response.
  • Lightweight aluminum spool of extra large diameter assures high-speed performance. Requires only short movement to deliver high-capacity air flow. File-hard anodized surface, polished to an 8 micro-inch finish, withstands wear and abrasion; offers greatest sealing qualities, minimum friction and maximum speed. Spool is balanced so air pressure won’t affect its position.
  • Low-friction, positive sealing ring is actually two seals in one; an outer static seal and an inner dynamic seal bonded to a metallic spacer ring. The ring protects the inner seal from the radical compression absorbed by the other seal. Assures longest life with positive sealing.
  • Seal retainers keep inner and outer sealing surfaces in precise position for maximum reliability and efficiency. Combined with the non-compressible seal rings, Power- Master valve retainers eliminate tolerance build-up in the free stack height of both retainers and seals.
  • Free-floating piston with extra large surface area means faster response at lower pressures.
  • Manual non-locking overrides allow supplementary manual control an permits operating the valve when the electric power is off.
  • External pilot allows an independent air supply to be connected to the pilot port in the valve operator or subplate for air pilot pressure.
  • Wire leads of 24" allows simplified conduit wiring.
  • Solenoid coil removal. Unscrew hex nut and slip off the solenoid housing and coil.
  • Exhaust restrictors can be used in either or both exhaust port to provide speed control of cylinders. (Refer to Accessory Valve catalog SC-400.)



Notes
All valves on this page are also available in 24VDC. Substitute-04300 as the suffix in the model code for single solenoid models, or - 04242 for double solenoid valves. 120VAC and 24VDC are the only voltages available in 1" and 1- 1/4" models.




 Powermaster Repair Kits 


Image
Aventics PowerMaster® Repair Kits

Site created by ThomasNet Web Solutions and powered by Navigator Platform