Catalog

4 Way / 2 Position 1/4" NPT Solenoid & Air Pilot Operated

TECHNICAL DATA:

Port Sizes: 1/4" NPT

Working Pressure: Vacuum service to 150 PSI

Pilot Pressure:
    22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models)
    45 PSI minimum - Single Solenoid & Single Air Pilot
    45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models)
    Dual pressure applications acceptable when external pilot supply is used.
Flow: Cv 1.1

Temperature Range:
    Solenoid Valve +5ºF to +120ºF
    Air Pilot -20ºF to +175ºF
    Explosion Proof Solenoid: 0º to +150ºF
Media: Air (either lubricated or non-lubricated)

Seals: Buna-N

Manual Override: Locking

For all applications when supply pressure is 45 psi or higher. Use external pilot version if supply pressure is under 45 psi (including vacuum or dual pressure applications). Take care to note which version is required before ordering since internal/external conversion is not field convertible.

All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory.
Unit of Measure

Specifications

Old Part #

N/A PS 032010-7272 PS 32010-7272 PS-032010-07272 PS032010-7272 PS32010-7272

Input Power

N/A 12 VDC

Type

N/A Double Solenoid 4-Way, 2 Position

Pilot

N/A Internal

Port Size

N/A 1/4" NPT

Working Pressure

N/A Vacuum service to 150 PSI

Flow

N/A Cv

Temperature Range (Solenoid Valve)

N/A +5 to +120 ºF

Temperature Range (Air Pilot)

N/A -20 to +175 ºF

Media

N/A Air (either lubricated or non-lubricated)

Seals

N/A Buna-N

Manual Override

N/A Locking

Additional Specifications

Additional Specifications

N/A Flow: Cv 1.1

Temperature Range:
Solenoid Valve +5ºF to +120ºF
Air Pilot -20ºF to +175ºF
Explosion Proof Solenoid: 0º to +150ºF

Media: Air (either lubricated or non-lubricated)

Seals: Buna-N

Manual Override: Locking

All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory.

Electrical Data

Electrical Data

N/A
Standard Voltage
(all coils are rated for continues duty)
Power Consumption
Inrush Holding
110 VAC 50 Hz/120 VAC 60 Hz
24 VAC 50/60 Hz
6.4 VA 3.7 VA
12, 24 VDC 2.7 W

Voltage Tolerance: ±10%
NOTE: Electrical connectors must be ordered separately.
One per solenoid required, see Solenoid Connectors page.

Features

Features

N/A
  • The 1/4" 4-way, 5-ported CD07 Valve is an extremely versatile, yet compact, design. This low-profile spool type design will not only enhance the appearance of your equipment, but will save valuable engineering space. A new simplified internal design allows for consistently reliable performance and ease of operation.

  • The CD07 Valve is available with a wide range of solenoid, air pilot and mechanical operators. This new design allows each valve body to be readily STACKED through a convenient and simplified single pressure port bar. Unique optional solenoid connectors offer neon indicator lights for (AC) circuits and L.E.D. displays for (DC) circuits.

  • Standard Plug-In DIN Connection "Low wattage" (2.1W) solenoid and connector, available with or without built-in indicator light.

  • External Pilot: (not shown) Allows an independent air supply to be connected to the pilot port of the solenoid operator.

  • Manual Locking Overrides: Allow supplementary manual control and permit operating the valve when the electric power is off.

  • Solenoid Coil Removal: Un-screw coil retaining nut and slip off the coil.

  • Seal Spacers: New lightweight acetal cartridge assembly.

  • Manifold System: Common pressure port bar

Back To Top