Distributor to Industry, Inc.
1017 East Murdock Street
Wichita, Kansas 67214
Toll Free: 800.835.2838 Phone: 316.263.9511
Email: sales@trydti.com •
Website: www.trydti.com
|
|
|
|
Item # R432016588, Rexroth CD07 Double Solenoid Valves, 5/3
|
|
|
|
4 Way / 3 Position 1/4" NPT Double Solenoid Operated
TECHNICAL DATA: Port Sizes: 1/4" NPT Working Pressure: Vacuum service to 150 PSI Pilot Pressure:22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models) 45 PSI minimum - Single Solenoid & Single Air Pilot 45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models) Dual pressure applications acceptable when external pilot supply is used. Flow: Cv 1.1 Temperature Range: Solenoid Valve +5ºF to +120ºF Air Pilot -20ºF to + 175ºF Explosion Proof Solenoid: 0º to +150ºF Media: Air (either lubricated or non-lubricated) Seals: Buna-N Manual Override: Locking
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory.
|
|
|
|
|
|
|
|
|
|
|
|
Standard Voltage
(all coils are rated for continues duty) |
Power Consumption |
Inrush |
Holding |
110 VAC 50 Hz/120 VAC 60 Hz
24 VAC 50/60 Hz |
6.4 VA |
3.7 VA |
12, 24 VDC |
2.7 W |
Voltage Tolerance: ±10% NOTE: Electrical connectors must be ordered separately. One per solenoid required, see Solenoid Connectors page.
|
|
|
|
- The 1/4" 4-way, 5-ported CD07 Valve is an extremely versatile, yet compact, design. This low-profile spool type design will not only enhance the appearance of your equipment, but will save valuable engineering space. A new simplified internal design allows for consistently reliable performance and ease of operation.
- The CD07 Valve is available with a wide range of solenoid, air pilot and mechanical operators. This new design allows each valve body to be readily STACKED through a convenient and simplified single pressure port bar. Unique optional solenoid connectors offer neon indicator lights for (AC) circuits and L.E.D. displays for (DC) circuits.
- Standard Plug-In DIN Connection "Low wattage" (2.1W) solenoid and connector, available with or without built-in indicator light.
- External Pilot: (not shown) Allows an independent air supply to be connected to the pilot port of the solenoid operator.
- Manual Locking Overrides: Allow supplementary manual control and permit operating the valve when the electric power is off.
- Solenoid Coil Removal: Un-screw coil retaining nut and slip off the coil.
- Seal Spacers: New lightweight acetal cartridge assembly.
- Manifold System: Common pressure port bar
|
|
|
|
|
|
|
|
|
|
|
|
|
|