Item # R432030358, Rexroth Series 840 4-Way Directional Control Valve
|
|
|
|
4 Way / 2 Position Poppet Valves Single & Double Solenoid, Single & Double Air Pilot
TECHNICAL DATA: Port Sizes: Integrated Fittings: 1/4" O.D. x 0.040" wall poly tubing (grey tube nuts) Flow: Cv= 0.20 Working Pressure:20 psi minimum (External pilots not available) 150 psi maximum (Below 105ºF) - solenoid & air pilot valves 115 psi maximum (105ºF -122ºF) - solenoid valves 115 psi maximum (105ºF - 140ºF) - air pilot valves No vacuum service Temperature Range:+5º to +122º F (20-115 psi)- solenoid valves +5º to +140º F (20-150 psi) - air pilot valves +5º to 105º F (20-150 psi) - solenoid & air pilot valves Media: Air (either lubricated or non-lubricated) Materials: Polyacetal Engineering Plastic with polyurethane seals and diaphragm Weight: 2.6 oz. (single solenoid) Manual Override: Locking Voltage Tolerance: ± 10%
Note: Valves on this page are not supplied with connectors. Connectors must be ordered separately. See The Wireways, Connectors and Manifolds section.
|
|
|
|
|
|
|
|
|
|
|
|
Standard Voltages (all coils are rated for continuous duty) |
Power Consumption |
Inrush |
Holding |
24, 120 VAC (50/60 Hz) |
2.9 VA |
2.0 VA |
12, 24 VDC |
1.6 W |
|
|
|
|
- 4 way/4 ported directional control valve.
- Compact and lightweight (only 2.6 oz. and requires less than 3 cubic inches of space).
- Designed to operate on non-lubricated air.
- Integral fitting (for 1/4" plastic tubing) for fast, leak free connections.
- Modular wire way system
- NEMA 4 Electrical Protection (valve only)
- UL Recognized
- "Clip type" valve to manifold mounting means valve installation and removal takes only seconds (similar to Type 740™ concept).
- Polyacetal Engineering Plastic construction provides excellent corrosion resistance.
- Poppet type valve design provides millions of trouble free cycles.
- Manual override standard.
- Twist lock coil design (no tools required) permits convenient interchangeability between AC and DC coils.
- 3 snap together modular manifold sections facilitate most manifold requirements (accommodates 3/8" O.D. tubing for both supply and exhaust).
- Cycle life - 20-100 million cycles
- Response time:
Supply pressure 90 psi Energized-(0-81 psi): 16ms De-energized (90-9 psi): 18ms Response time based on 24 VDC Single Solenoid
|
|
|
|
|
|
|
|
|
|
|
|
|
|