(20)4 Way / 2 Position 1/4" NPT Solenoid & Air Pilot Operated
TECHNICAL DATA: Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models) 45 PSI minimum - Single Solenoid & Single Air Pilot 45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models) Dual pressure applications acceptable when external pilot supply is used.
(3)4 Way / 2 Position 1/4" NPT Explosion Proof Solenoid Valves for Hazardous Locations
TECHNICAL DATA: Port Sizes: 1/4" NPT Working Pressure: Vacuum service to 150 PSI Pilot Pressure:
22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models) 45 PSI minimum - Single Solenoid & Single Air Pilot 45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models) Dual pressure applications acceptable when external pilot supply is used.
Flow: Cv 1.1 Temperature Range:
Solenoid Valve +5ºF to +120ºF Air Pilot -20ºF to +175ºF Explosion Proof Solenoid: 0º to +150ºF
Media: Air (either lubricated or non-lubricated) Seals: Buna-N Manual Override: Locking
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory.
CSA: Class I, Zone 1, Ex m II T4 Class I, Div. 1, Gr. A, B, C and D Class II, GR. E, F and G, Class III; T4
FM: Class I, Zone 1, Aex m II T4 Class I, Div. 1, Gr. A, B, C and D Class II, GR. E, F and G, Class III; T4/Asset/a1350.jpg
(2)4 Way / 2 Position 1/4" NPT Air Pilot Operated Valves
TECHNICAL DATA: Port Sizes: 1/4" NPT Working Pressure: Vacuum service to 150 PSI Pilot Pressure:
22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models) 45 PSI minimum - Single Solenoid & Single Air Pilot 45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models) Dual pressure applications acceptable when external pilot supply is used.
Flow: Cv 1.1 Temperature Range:
Solenoid Valve +5ºF to +120ºF Air Pilot -20ºF to +175ºF Explosion Proof Solenoid: 0º to +150ºF
Media: Air (either lubricated or non-lubricated) Seals: Buna-N Manual Override: Locking
For all applications when supply pressure is 45 psi or higher. Use external pilot version if supply pressure is under 45 psi (including vacuum or dual pressure applications). Take care to note which version is required before ordering since internal/external conversion is not field convertible.
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory.
CSA: Class I, Zone 1, Ex m II T4 Class I, Div. 1, Gr. A, B, C and D Class II, GR. E, F and G, Class III; T4
FM: Class I, Zone 1, Aex m II T4 Class I, Div. 1, Gr. A, B, C and D Class II, GR. E, F and G, Class III; T4
/Asset/a1350.jpg
(13)4 Way / 3 Position 1/4" NPT Double Solenoid Operated
TECHNICAL DATA: Port Sizes: 1/4" NPT Working Pressure: Vacuum service to 150 PSI Pilot Pressure:
22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models) 45 PSI minimum - Single Solenoid & Single Air Pilot 45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models) Dual pressure applications acceptable when external pilot supply is used.
Flow: Cv 1.1 Temperature Range:
Solenoid Valve +5ºF to +120ºF Air Pilot -20ºF to + 175ºF Explosion Proof Solenoid: 0º to +150ºF
Media: Air (either lubricated or non-lubricated) Seals: Buna-N Manual Override: Locking
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory./Asset/a1356.jpg
(3)4 Way / 3 Position 1/4" NPT Double Air Pilot Operated
TECHNICAL DATA: Port Sizes: 1/4" NPT Working Pressure: Vacuum service to 150 PSI Pilot Pressure:
22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models) 45 PSI minimum - Single Solenoid & Single Air Pilot 45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models) Dual pressure applications acceptable when external pilot supply is used.
Flow: Cv 1.1 Temperature Range:
Solenoid Valve +5ºF to +120ºF Air Pilot -20ºF to + 175ºF Explosion Proof Solenoid: 0º to +150ºF
Media: Air (either lubricated or non-lubricated) Seals: Buna-N Manual Override: Locking
For all applications when supply pressure is 45 psi or higher. Use external pilot version if supply pressure is under 45 psi (including vacuum or dual pressure applications). Take care to note which version is required before ordering since internal/external conversion is not field convertible.
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory./Asset/a1359.jpg
(7)1/4" NPT Pressure Port Bar Manifold System for CD07 Valves
Will accommodate a mixture of all types of CD07 valves and operators. However, the Rotary Lever, Plain Knob and Explosion Proof operators may not have operating clearance.
How to Order: Select the valves or combination of CD07 valves. Then select the number of stations by the part number listed below:/Asset/a1362.jpg