Catalog
            2 Position Subbase Mounted
Single or Double Air Pilot Operated
TECHNICAL DATA:
Port Sizes: 1/4" & 3/8" NPTF
Working Pressure:
Flow: Cv 1.0 (1000 Nl/min)
Temperature Range: -20ºF to +160ºF (-29ºC to 71ºC)
Media: Air and inert gases (In service higher than 18 cycles per minute or with continuous air flow, a lubricator is recommended.)
Materials:
Note: Other coil voltages are available - selection will be done at checkout.
Single or Double Air Pilot Operated
TECHNICAL DATA:
Port Sizes: 1/4" & 3/8" NPTF
Working Pressure:
- Valve inlet: 200 psi (13.8 bar) maximum with external pilot
150 psi (10.3 bar) maximum with internal pilot
Flow: Cv 1.0 (1000 Nl/min)
Temperature Range: -20ºF to +160ºF (-29ºC to 71ºC)
Media: Air and inert gases (In service higher than 18 cycles per minute or with continuous air flow, a lubricator is recommended.)
Materials:
- Body, subplate and operators: Die cast anodized aluminum
Spool: Machined from high-tensile anodized aluminum
Seals: Buna-N specially treated
Note: Other coil voltages are available - selection will be done at checkout.
                    Unit of Measure
                    
               
        
            Specifications
| Old Part # | N/A PJ 031660 PJ 31660 PJ031660 PJ-031660-00000 PJ31660 | 
| Subbase | N/A With 3/8" subbase | 
| Type | N/A Double Air Pilot | 
| Weight | N/A 2.13 lb0.97 kg | 
| Port Size | N/A 1/4" & 3/8" NPTF | 
| Minimum Pilot Pressure | N/A 2 position: 15 psi (1 bar) Spring return models: 25 psi (1.7 bar) | 
| Flow | N/A Cv 1.0 (1000 Nl/min) | 
| Temperature Range | N/A -20 to +160 ºF-29 to 71 ºC | 
| Manual Override | N/A Non-Locking | 
| Molded Coil | N/A Standard | 
| Lead Length | N/A 24 in. | 
| Coil Voltage1 | N/A 120VAC@60 Hz Primary, 38VDC Secondary 12VDC Primary, 42VAC@60 Hz Secondary 240VAC@60 Hz Primary, 70VDC Secondary 24VDC Primary, 86VAC@60 Hz Secondary 480VAC@60 Hz Primary, 145VDC Secondary Standard 120VAC@60 Hz Coil | 
Electrical Data
| Electrical Data | N/A 
 Molded Coil: Standard Lead Length: 24" | |||||||||||
Other Notes
| Other Notes | N/A Solenoid pilot pressure must be a minimum of 25 psi with return springs, 15 psi less return springs and a maximum of 150 psi. A flush, non-locking manual override is standard for manual operation when the electric power is off. Other optional features are available upon request such as high pressure (200 psi) solenoids. | 
Features
| Features | N/A 
 | 
- 1 Primary and secondary voltages will be stenciled on the solenoid data plate.

 
			
		   
						