TECHNICAL DATA:
Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
TECHNICAL DATA:
Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
Temperature Range:
Seals: Buna-N
Manual Override: Locking
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory.
CSA:
Class I, Zone 1, Ex m II T4
Class I, Div. 1, Gr. A, B, C and D
Class II, GR. E, F and G, Class III; T4
FM:
Class I, Zone 1, Aex m II T4
Class I, Div. 1, Gr. A, B, C and D
Class II, GR. E, F and G, Class III; T4 /Asset/a1350.jpg
TECHNICAL DATA:
Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
Temperature Range:
Seals: Buna-N
Manual Override: Locking
For all applications when supply pressure is 45 psi or higher. Use external pilot version if supply pressure is under 45 psi (including vacuum or dual pressure applications). Take care to note which version is required before ordering since internal/external conversion is not field convertible.
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory.
CSA:
Class I, Zone 1, Ex m II T4
Class I, Div. 1, Gr. A, B, C and D
Class II, GR. E, F and G, Class III; T4
FM:
Class I, Zone 1, Aex m II T4
Class I, Div. 1, Gr. A, B, C and D
Class II, GR. E, F and G, Class III; T4 /Asset/a1350.jpg
TECHNICAL DATA:
Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
Temperature Range:
Seals: Buna-N
Manual Override: Locking
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory. /Asset/a1356.jpg
TECHNICAL DATA:
Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
Temperature Range:
Seals: Buna-N
Manual Override: Locking
For all applications when supply pressure is 45 psi or higher. Use external pilot version if supply pressure is under 45 psi (including vacuum or dual pressure applications). Take care to note which version is required before ordering since internal/external conversion is not field convertible.
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory. /Asset/a1359.jpg
Will accommodate a mixture of all types of CD07 valves and operators. However, the Rotary Lever, Plain Knob and Explosion Proof operators may not have operating clearance.
How to Order: Select the valves or combination of CD07 valves. Then select the number of stations by the part number listed below: /Asset/a1362.jpg
Aventics CD07 Single and Double Solenoid Valves, 5/2
(20) 4 Way / 2 Position 1/4" NPT Solenoid & Air Pilot OperatedTECHNICAL DATA:
Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
- 22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models)
45 PSI minimum - Single Solenoid & Single Air Pilot
45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models)
Dual pressure applications acceptable when external pilot supply is used.
Aventics CD07 Explosion Proof Valves
(3) 4 Way / 2 Position 1/4" NPT Explosion Proof Solenoid Valves for Hazardous LocationsTECHNICAL DATA:
Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
- 22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models)
45 PSI minimum - Single Solenoid & Single Air Pilot
45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models)
Dual pressure applications acceptable when external pilot supply is used.
Temperature Range:
- Solenoid Valve +5ºF to +120ºF
Air Pilot -20ºF to +175ºF
Explosion Proof Solenoid: 0º to +150ºF
Seals: Buna-N
Manual Override: Locking
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory.
CSA:
Class I, Zone 1, Ex m II T4
Class I, Div. 1, Gr. A, B, C and D
Class II, GR. E, F and G, Class III; T4
FM:
Class I, Zone 1, Aex m II T4
Class I, Div. 1, Gr. A, B, C and D
Class II, GR. E, F and G, Class III; T4 /Asset/a1350.jpg
Rexroth CD07 Air Pilot Operated Valves (4- Way/2 Position)
(2) 4 Way / 2 Position 1/4" NPT Air Pilot Operated ValvesTECHNICAL DATA:
Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
- 22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models)
45 PSI minimum - Single Solenoid & Single Air Pilot
45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models)
Dual pressure applications acceptable when external pilot supply is used.
Temperature Range:
- Solenoid Valve +5ºF to +120ºF
Air Pilot -20ºF to +175ºF
Explosion Proof Solenoid: 0º to +150ºF
Seals: Buna-N
Manual Override: Locking
For all applications when supply pressure is 45 psi or higher. Use external pilot version if supply pressure is under 45 psi (including vacuum or dual pressure applications). Take care to note which version is required before ordering since internal/external conversion is not field convertible.
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory.
CSA:
Class I, Zone 1, Ex m II T4
Class I, Div. 1, Gr. A, B, C and D
Class II, GR. E, F and G, Class III; T4
FM:
Class I, Zone 1, Aex m II T4
Class I, Div. 1, Gr. A, B, C and D
Class II, GR. E, F and G, Class III; T4 /Asset/a1350.jpg
Rexroth CD07 Double Solenoid Valves, 5/3
(13) 4 Way / 3 Position 1/4" NPT Double Solenoid OperatedTECHNICAL DATA:
Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
- 22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models)
45 PSI minimum - Single Solenoid & Single Air Pilot
45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models)
Dual pressure applications acceptable when external pilot supply is used.
Temperature Range:
- Solenoid Valve +5ºF to +120ºF
Air Pilot -20ºF to + 175ºF
Explosion Proof Solenoid: 0º to +150ºF
Seals: Buna-N
Manual Override: Locking
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory. /Asset/a1356.jpg
Rexroth CD07 Double Air Pilot Valves (4-Way/3 Position)
(3) 4 Way / 3 Position 1/4" NPT Double Air Pilot OperatedTECHNICAL DATA:
Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
- 22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models)
45 PSI minimum - Single Solenoid & Single Air Pilot
45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models)
Dual pressure applications acceptable when external pilot supply is used.
Temperature Range:
- Solenoid Valve +5ºF to +120ºF
Air Pilot -20ºF to + 175ºF
Explosion Proof Solenoid: 0º to +150ºF
Seals: Buna-N
Manual Override: Locking
For all applications when supply pressure is 45 psi or higher. Use external pilot version if supply pressure is under 45 psi (including vacuum or dual pressure applications). Take care to note which version is required before ordering since internal/external conversion is not field convertible.
All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory. /Asset/a1359.jpg
Rexroth CD07 Pressure Port Manifold Bar
(7) 1/4" NPT Pressure Port Bar Manifold System for CD07 ValvesWill accommodate a mixture of all types of CD07 valves and operators. However, the Rotary Lever, Plain Knob and Explosion Proof operators may not have operating clearance.
How to Order: Select the valves or combination of CD07 valves. Then select the number of stations by the part number listed below: /Asset/a1362.jpg