Summary of Specifications For Ceram Valves
Single Subbasee (Sise ported) 1/4" or 3/8" NPT Ports and End Ported Manifold 1/4" NPT Ports
TECHNICAL DATA:
Port Sizes:
1/2" - 3/4” ISO Size III, 1" ISO Size IVWorking Pressure:
29 psi (2.0 bar) minimum, all 2 position valves
44 psi (3.0 bar) minimum, all 3 position valves
150 psi (10.3 bar) maximum
(Intrinsically Safe versions: Maximum external pilot pressure is 115 psi or 7.9 bar)
SIZES III & IV
36 psi (2.5 bar) minimum, all 2 position valve
44 psi (3.0 bar) minimum, all 3 position valve
150 PSI(10.3 bar) maximum
(Intrinsically Safe versions: Maximum external pilot pressure is 115 psi or 7.9 bar) /Asset/a1625.jpg
STATION SEGMENT
Each station segment kit comes complete with pipe plugs (to block unused delivery ports), fastening hardware, and a gasket. The gasket is placed between each station segment. The standard sealing gasket (A GASKET. PART NUMBER - R432008985) included has windows open for ports 1,3, & 5.
END PLATE KITS
Consists of two end plates complete with pipe plugs (to block unused supply and exhaust ports), fastening hardware, and the standard sealing gasket (A GASKET, Part Number - R432008985)
EASY MANIFOLD ASSEMBLY
Use a 4 mm hex (Allen) wrench to assemble the manifolds. Nuts and bolts (included in each kit) are used to hold the manifolds together. An extra long 4 mm wrench can be used for longer manifolds for more rapid assembly.
DUAL MANIFOLD SUPPLY PRESSURE
Supply pressure can be supplied to both ends of the manifold by simply not installing the pipe plugs supplied with the end plate kit. This is generally considered normal practice if more than 3 valves are energized at the same time.
MANIFOLD WITH TWO DIFFERENT SUPPLY PRESSURES
Different supply pressures can be provided by placing blocking gasket B (1821015043) between two of the station segments to divide the two different pressures.
PLEASE CPNSULT FACTORY WITH SPECIAL APPLICATIONS 1 AND 2 BELOW:
Use a 1/8 diameter drill at the 14 end to remove the thin wall on manifold station segment R432015314. Clean throughly.
NOTE: This wall is required to operate air piloted valves on manifold. /Asset/a1628.jpg
Rexroth Ceram™ Subbases, Size 1
(5) Specified by industries that demand tough valves due to their harsh operating environment. Ceram™ valves are very prevalent in industries where ordinary valves just don’t last. Industries such as: tire plants, foundries, paper mills, steel plants, concrete batch plants, sawmills, plywood and board plants, automotive assembly, glass manufacturers, rubber and plastics, sheet metal fabrication, etc.Summary of Specifications For Ceram Valves
Single Subbasee (Sise ported) 1/4" or 3/8" NPT Ports and End Ported Manifold 1/4" NPT Ports
TECHNICAL DATA:
Port Sizes:
1/2" - 3/4” ISO Size III, 1" ISO Size IVWorking Pressure:
- 0 to 150 psi (0 to 10.3 bar)
(Intrinsically Safe versions: Maximum internal pilot valve pressure is 115 psi or 7.9 bar)
Vacuum applications: to 24" Hg
- SIZES I & II
29 psi (2.0 bar) minimum, all 2 position valves
44 psi (3.0 bar) minimum, all 3 position valves
150 psi (10.3 bar) maximum
(Intrinsically Safe versions: Maximum external pilot pressure is 115 psi or 7.9 bar)
SIZES III & IV
36 psi (2.5 bar) minimum, all 2 position valve
44 psi (3.0 bar) minimum, all 3 position valve
150 PSI(10.3 bar) maximum
(Intrinsically Safe versions: Maximum external pilot pressure is 115 psi or 7.9 bar) /Asset/a1625.jpg
Rexroth Ceram™ Manifolds, Size 1
END PORTED MANIFOLDSSTATION SEGMENT
Each station segment kit comes complete with pipe plugs (to block unused delivery ports), fastening hardware, and a gasket. The gasket is placed between each station segment. The standard sealing gasket (A GASKET. PART NUMBER - R432008985) included has windows open for ports 1,3, & 5.
END PLATE KITS
Consists of two end plates complete with pipe plugs (to block unused supply and exhaust ports), fastening hardware, and the standard sealing gasket (A GASKET, Part Number - R432008985)
EASY MANIFOLD ASSEMBLY
Use a 4 mm hex (Allen) wrench to assemble the manifolds. Nuts and bolts (included in each kit) are used to hold the manifolds together. An extra long 4 mm wrench can be used for longer manifolds for more rapid assembly.
DUAL MANIFOLD SUPPLY PRESSURE
Supply pressure can be supplied to both ends of the manifold by simply not installing the pipe plugs supplied with the end plate kit. This is generally considered normal practice if more than 3 valves are energized at the same time.
MANIFOLD WITH TWO DIFFERENT SUPPLY PRESSURES
Different supply pressures can be provided by placing blocking gasket B (1821015043) between two of the station segments to divide the two different pressures.
PLEASE CPNSULT FACTORY WITH SPECIAL APPLICATIONS 1 AND 2 BELOW:
- Manifold With Two Different Supply Pressures & Common Ext. Pillot
- Manifold With Three Different Supply Pressures
Use a 1/8 diameter drill at the 14 end to remove the thin wall on manifold station segment R432015314. Clean throughly.
NOTE: This wall is required to operate air piloted valves on manifold. /Asset/a1628.jpg