(6) Specified by industries that demand tough valves due to their harsh operating environment. Ceram™ valves are very prevalent in industries where ordinary valves just don’t last. Industries such as: tire plants, foundries, paper mills, steel plants, concrete batch plants, sawmills, plywood and board plants, automotive assembly, glass manufacturers, rubber and plastics, sheet metal fabrication, etc.Summary of Specifications For Ceram Valves
End Ported Manifold 1/2" NPT delivery port and Single Subbase (side ported) 3/8" or 1/2" NPT Ports
TECHNICAL DATA:
Port Sizes:
1/2" - 3/4” ISO Size III, 1" ISO Size IVWorking Pressure:
- 0 to 150 psi (0 to 10.3 bar)
(Intrinsically Safe versions: Maximum internal pilot valve pressure is 115 psi or 7.9 bar)
Vacuum applications: to 24" Hg
- SIZES I & II
29 psi (2.0 bar) minimum, all 2 position valves
44 psi (3.0 bar) minimum, all 3 position valves
150 psi (10.3 bar) maximum
(Intrinsically Safe versions: Maximum external pilot pressure is 115 psi or 7.9 bar)
SIZES III & IV
36 psi (2.5 bar) minimum, all 2 position valve
44 psi (3.0 bar) minimum, all 3 position valve
150 PSI(10.3 bar) maximum
(Intrinsically Safe versions: Maximum external pilot pressure is 115 psi or 7.9 bar) /Asset/a1641.jpg
Aventics Ceram™ Manifolds, Size 2
Aventics End Ported Manifolds
Station Segment
Each station segment kit comes complete with hardware, seals, and a sealing plate. The sealing plate is placed between each segment to ensure sealing between the Buna N gaskets. The standard sealing plate (PLATE A) included has windows open for ports 1,3, & 5.
End Plate Kits
Consists of two end plates complete with hardware and seals. Pressure is blocked on Size II end plates with 3/4" pipe plugs (included).
Easy Manifold Assembly
Use a 3 mm hex key to partially back out (approximately 4 turns counter clockwise) the installed set screw. Press the mating station segment or end plate to the manifold assembly with a sealing plate between the two, and turn the hex key clockwise to complete assembly. Tighten set screws on both sides of the manifold.
Dual Manifold Supply Pressure
On size II manifolds, simply remove the pipe plugs. This is standard practice if more than 3 valves are energized at the same time and flow is critical to the application.
Manifold With Two Different Supply Pressure
On size II manifolds, place plate B where the pressure division is desired and remove pipe plugs from the end cover.
Common External Pilot Pressure
If a common external pilot is required (normally if supply pressure is below minimum pressure or a vacuum supply is used) for the entire length of the manifold, all standard plates (plate A) must be replaced by plate C. Individual valves can be externally piloted by connecting the external pilot supply to port 14 on the end of the station segment.
PLEASE CPNSULT FACTORY WITH SPECIAL APPLICATIONS 1 AND 2 BELOW:
- Manifold With Two Different Supply Pressures & Common Ext. Pillot
- Manifold With Three Different Supply Pressures