Catalog
2 and 3 Position Subbase Mounted
Lever Operated
TECHNICAL DATA:
Port Sizes: 1/4" & 3/8" NPTF
Working Pressure:
Flow: Cv 1.0 (1000 Nl/min)
Temperature Range: -20ºF to +160ºF (-29ºC to 71ºC)
Media: Air and inert gases (In service higher than 18 cycles per minute or with continuous air flow, a lubricator is recommended.)
Materials:
Note: Other coil voltages are available - selection will be done at checkout.
Lever Operated
TECHNICAL DATA:
Port Sizes: 1/4" & 3/8" NPTF
Working Pressure:
- Valve inlet: 200 psi (13.8 bar) maximum with external pilot
150 psi (10.3 bar) maximum with internal pilot
Flow: Cv 1.0 (1000 Nl/min)
Temperature Range: -20ºF to +160ºF (-29ºC to 71ºC)
Media: Air and inert gases (In service higher than 18 cycles per minute or with continuous air flow, a lubricator is recommended.)
Materials:
- Body, subplate and operators: Die cast anodized aluminum
Spool: Machined from high-tensile anodized aluminum
Seals: Buna-N specially treated
Note: Other coil voltages are available - selection will be done at checkout.
Unit of Measure
Specifications
Old Part # |
N/A PJ 010200 PJ 10200 PJ010200 PJ-010200-00000 PJ10200 |
Subbase |
N/A Without subbase |
Type |
N/A 2 Position without Spring |
Weight |
N/A 2.50 lb1.13 kg |
Minimum Pilot Pressure |
N/A 2 position: 15 psi (1 bar) Spring return models: 25 psi (1.7 bar) |
Flow |
N/A Cv 1.0 (1000 Nl/min) |
Temperature Range |
N/A -20 to +160 ºF-29 to 71 ºC |
Manual Override |
N/A Non-Locking |
Molded Coil |
N/A Standard |
Lead Length |
N/A 24 in. |
Coil Voltage1 | N/A 120VAC@60 Hz Primary, 38VDC Secondary 12VDC Primary, 42VAC@60 Hz Secondary 240VAC@60 Hz Primary, 70VDC Secondary 24VDC Primary, 86VAC@60 Hz Secondary 480VAC@60 Hz Primary, 145VDC Secondary Standard 120VAC@60 Hz Coil |
Electrical Data
Electrical Data |
N/A
Molded Coil: Standard Lead Length: 24" |
Other Notes
Other Notes |
N/A Solenoid pilot pressure must be a minimum of 25 psi with return springs, 15 psi less return springs and a maximum of 150 psi. A flush, non-locking manual override is standard for manual operation when the electric power is off. Other optional features are available upon request such as high pressure (200 psi) solenoids. |
Features
Features |
N/A
|
- 1 Primary and secondary voltages will be stenciled on the solenoid data plate.