Catalog

Type: Pilot operated sequence valve
Supply Pressure: 200 PSI Max. Except P -059158-00045 (300 PSI)
Control Pressure: 140 psi max.
Temperature range: -40°F to 160°F
Media: Air or inert gas
Port Size:
    Control port (port 10), breather port (port 1): 1/4" NPT
    All other ports: 3/8" NPT
Operating Characteristics
The Relayair® Valve has three basic uses:
  1. As a nongraduated relay to provide a large flow of air from a separate source when piloted by small amount of control media and to stop this flow and exhaust the air to atmosphere when the control pressure is vented.
  2. As an interlock to govern the flow in one circuit by placing its control in another independent circuit.
  3. As a pressure-sensitive sequence valve for such circuit functions as timing, cycling, etc.
Application Notes
RELAYAIR Valves operated by pilot pressures less than 35 psi utilize one control spring while valves operated by pilot pressures greater than 35 psi use two springs. To obtain pilot pressures less than 10 psi, two diaphragms are used in series.
Unit of Measure

Specifications

Old Part #

N/A P -059155-00025 P-059155-25 P059155-25 P-59155-25 P59155-25

Pilot Pressure

N/A 25 psi

Model Designation

N/A H-5

Type

N/A Pilot Operated Sequence Valve

Supply Pressure

N/A 200 psi Max. Except P -059158-00045 (300 PSI)

Maximum Control Pressure

N/A 140 psi

Temperature Range

N/A -40 to 160 ºF

Media

N/A Air or inert gas

Dimensions

A

N/A 13/16 in.

B

N/A 4-3/8 in.

C

N/A 1/2 in.

D - NPTF

N/A 1/4-18 in.

E

N/A 2-7/16 in.

F

N/A 1-7/8 in.

G

N/A 9/32 in.

H

N/A 7-3/4 in.

I - NPTF

N/A 3/8-18 in.

J

N/A 15/16 in.

K

N/A 3/16 in.

L

N/A 27/32 in.

M

N/A 1/4 in.

N - NPT

N/A 1/4-18 in.

O

N/A 3-1/8 in.

P

N/A 7-3/8 in.

Q

N/A Ø7/16 in.

R

N/A 9/16 in.

S

N/A 4-3/8 in.
T1 N/A 13/16 in.

U (3 Places)

N/A 13/32 in.

V

N/A Ø7/16 in.

W

N/A 2 in.

X

N/A Ø7/16 in.

Y

N/A 3-1/2 in.

Z

N/A 1-3/4 in.
  • 1 Clearance required for removal.

Back To Top