Print Back
Includes all user serviceable rubber parts normally required.
Unit of Measure

Specifications

Old Part #

P -068899-00000

Description

120VAC 50/60Hz

Type

Solenoid Kit

ATTENTION

ATTENTION

DO NOT remove the static base. Special fixtures are required to reinstall plates to factory specifications. Roller bearings and ceramic plate stack are calibrated to obtain proper mechanical pre-loading. Therefore, field disassembly is not recommended for the plate/bearing assembly. The ceramic slide plates do not require maintenance under normal operating conditions and should not be removed from the valve - consult factory if plate maintenance is required. There are no seals for the static base/ceramic plate assembly contained in repair kits.