Catalog
4 Way / 2 & 3 Position Solenoid & Air Pilot Operated Diaphragm-Poppet Valve
TECHNICAL DATA:
Port Sizes:
Materials: Polyacetal Engineering plastic with Buna N seals and diaphragms
Combination Manual Override: Locking & Non-Locking
Electrical connectors must be ordered separately. One per solenoid required. See complete listing on Solenoid Connectors page.
Recommended Tubing:
Valves designed for 10mm O.D. x 1mm wall poly tubing are also available.
Adapters available: 1/4" O.D. x 0.040 wall - poly tubing.
Tube nuts are supplied with each valve for 3/8" x 0.062 wall poly tubing.
Note: Electrical connector must be ordered separately. One per solenoid required, see Solenoid Connectors page. All valves on this page come with 3/8” tube nuts designed to accommodate 3/8" x 0.062" wall poly tubing. Valves with tube nuts for 5/16" (8mm) tubing, 10mm tubing, and push-in fitting style bodies available.
TECHNICAL DATA:
Port Sizes:
- Integrated Fittings for 3/8", 5/16", and 8mm tubing
Push-in fitting styles bodies available for metric tubing only (2 position only)
- 20 PSI minimum
150 PSI maximum
External Pilots not available
- Cv=0.7 - with Integrated Fittings
(Cv=1.3 - comparable flow to threaded part valve)
- Solenoid Valve +5°F to 122°F
Air Pilot +5°F to 140°F
Materials: Polyacetal Engineering plastic with Buna N seals and diaphragms
Combination Manual Override: Locking & Non-Locking
Electrical connectors must be ordered separately. One per solenoid required. See complete listing on Solenoid Connectors page.
Recommended Tubing:
- Standard 3/8" O.D> x 0.062" wall - poly tubing
5/16" O.D. x 0.040 wall - nylon tubing
8mm x 1.00mm wall poly tubing
Valves designed for 10mm O.D. x 1mm wall poly tubing are also available.
Adapters available: 1/4" O.D. x 0.040 wall - poly tubing.
Tube nuts are supplied with each valve for 3/8" x 0.062 wall poly tubing.
Note: Electrical connector must be ordered separately. One per solenoid required, see Solenoid Connectors page. All valves on this page come with 3/8” tube nuts designed to accommodate 3/8" x 0.062" wall poly tubing. Valves with tube nuts for 5/16" (8mm) tubing, 10mm tubing, and push-in fitting style bodies available.
Unit of Measure
Specifications
Old Part # |
N/A PW-067697-00006 |
Voltage |
N/A 24 VAC 50/60 Hz |
No. of Positions |
N/A 2 |
Type |
N/A Single Solenoid with Air Spring Return |
Voltage Tolerance |
N/A ± 10% |
Temperature Range |
N/A +5 to 122 ºF |
Min. Working Pressure |
N/A 20 psi |
Maximum Working Pressure |
N/A 150 psi |
Media |
N/A Air (either lubricated or non-lubricated) |
Material |
N/A Polyacetal Engineering plastic with Buna N seals and diaphragms |
Combination Manual Override |
N/A Locking & Non-Locking |
Electrical Data
Electrical Data |
N/A
|
Features
Features |
N/A
Single solenoid valves are equipped with a convertible manual override button. Valve comes standard with extended locking override. By snipping tab off of plastic button, override becomes non-locking extended. By snipping button at first scored line, it becomes a flush non-locking override. By snipping at second scored line, a flush locking override is obtained, requiring a screwdriver to actuate. |