Catalog
4 Way / 2 & 3 Position Solenoid & Air Pilot Operated Diaphragm-Poppet Valve
TECHNICAL DATA:
Port Sizes:
Materials: Polyacetal Engineering plastic with Buna N seals and diaphragms
Combination Manual Override: Locking & Non-Locking
Electrical connectors must be ordered separately. One per solenoid required. See complete listing on Solenoid Connectors page. All valves on this page come with 3/8” tube nuts designed to accommodate 3/8" x 0.062" wall poly tubing.
Recommended Tubing:
Valves designed for 10mm O.D. x 1mm wall poly tubing are also available.
Adapters available: 1/4" O.D. x 0.040 wall - poly tubing.
Tube nuts are supplied with each valve for 3/8" x 0.062 wall poly tubing.
The external non-locking manual override button may be pushed from one side to the other to select which delivery port is pressurized initially.
Warning: Do not energize both solenoids at same time or all ports may be pressurized or exhausted.
TECHNICAL DATA:
Port Sizes:
- Integrated Fittings for 3/8", 5/16", and 8mm tubing
Push-in fitting styles bodies available for metric tubing only (2 position only)
- 20 PSI minimum
150 PSI maximum
External Pilots not available
- Cv=0.7 - with Integrated Fittings
(Cv=1.3 - comparable flow to threaded part valve)
- Solenoid Valve +5°F to 122°F
Air Pilot +5°F to 140°F
Materials: Polyacetal Engineering plastic with Buna N seals and diaphragms
Combination Manual Override: Locking & Non-Locking
Electrical connectors must be ordered separately. One per solenoid required. See complete listing on Solenoid Connectors page. All valves on this page come with 3/8” tube nuts designed to accommodate 3/8" x 0.062" wall poly tubing.
Recommended Tubing:
- Standard 3/8" O.D> x 0.062" wall - poly tubing
5/16" O.D. x 0.040 wall - nylon tubing
8mm x 1.00mm wall poly tubing
Valves designed for 10mm O.D. x 1mm wall poly tubing are also available.
Adapters available: 1/4" O.D. x 0.040 wall - poly tubing.
Tube nuts are supplied with each valve for 3/8" x 0.062 wall poly tubing.
The external non-locking manual override button may be pushed from one side to the other to select which delivery port is pressurized initially.
Warning: Do not energize both solenoids at same time or all ports may be pressurized or exhausted.
Unit of Measure
Specifications
Description |
N/A without coil |
Type |
N/A Closed Center |
Warning |
N/A Do not energize both solenoids at same time or all ports may be pressurized or exhausted. |
Voltage Tolerance |
N/A ± 10% |
Min. Working Pressure |
N/A 20 psi |
Maximum Working Pressure |
N/A 150 psi |
Temperature Range |
N/A +5 to 122 ºF |
Media |
N/A Air (either lubricated or non-lubricated) |
Material |
N/A Polyacetal Engineering plastic with Buna N seals and diaphragms |
Combination Manual Override |
N/A Locking & Non-Locking |
Electrical Data
Electrical Data |
N/A
|
Features
Features |
N/A
|