Print Back
4 Way / 2 and 3 Position Manifold Mounts & Gang Stacking

TECHNICAL DATA:

Port Sizes:
    Integrated Fittings for 3/8", 5/16", and 8mm tubing
    Push-in fitting styles bodies available for metric tubing only (2 position only)
Working Pressure:
    20 PSI minimum
    150 PSI maximum
    External Pilots not available
Flow:
    Cv=0.7 - with Integrated Fittings
    (Cv=1.3 - comparable flow to threaded part valve)
Temperature Range:
    Solenoid Valve +5°F to 122°F
    Air Pilot +5°F to 140°F
Media: Air (either lubricated or non-lubricated)
Materials: Polyacetal Engineering plastic with Buna N seals and diaphragms
Combination Manual Override: Locking & Non-Locking

Electrical connectors must be ordered separately. One per solenoid required. See complete listing on Solenoid Connectors page.

Recommended Tubing:
  • Standard 3/8" O.D> x 0.062" wall - poly tubing
    5/16" O.D. x 0.040 wall - nylon tubing
    8mm x 1.00mm wall poly tubing
Requires optional tube nut kit (R432015289)
Valves designed for 10mm O.D. x 1mm wall poly tubing are also available.
Adapters available: 1/4" O.D. x 0.040 wall - poly tubing.
Tube nuts are supplied with each valve for 3/8" x 0.062 wall poly tubing.

SHEAR PLUG KNOCKOUT
Ganged assembly-common supply pressure obtainable by knockout shear plugs.

Stack can be held together and mounted with readily available 1/8" "all thread" material.

MANIFOLD INSTALLATION NOTE:

The first and last segment should always be securely mounted to a plate. If more than five valves are used, every third valve segment should also be securely mounted.

Ordering Example
(4 Station Manifold)
1 - Inlet Segment
1 - End Segment
2 - Station Segment
Unit of Measure

Specifications

Old Part #

N/A P -067701-00000

Description

N/A Inlet Segment

Voltage Tolerance

N/A ± 10%

Min. Working Pressure

N/A 20 psi

Maximum Working Pressure

N/A 150 psi

Temperature Range

N/A +5 to 122 ºF

Media

N/A Air (either lubricated or non-lubricated)

Material

N/A Polyacetal Engineering plastic with Buna N seals and diaphragms

Combination Manual Override

N/A Locking & Non-Locking

Note

N/A
  • NEMA 4 Electrical protection
  • UL recognized & CSA approved coils version available
  • Packaged as a cylinder/valve combination with TaskMaster® cylinders sizes 1 1/2" thru 4". See catalog SC-200.
  • Integrated fittings
  • Adjustable built-in flo

Electrical Data

Electrical Data

N/A
Standard Voltage (all coils are rated for continuous duty) Power Consumption
Inrush Holding
24 VAC-50/60 Hz,
110V-50 Hz/120V-60 Hz
220V-50 Hz/240V
6.4 VA 3.7 VA
6, 12, 24 VDC 2.7 W

Features

Features

N/A Yellow lock tab on manifold segments are scored. This allows the end to be broken off (if desired), making it, tamper resistant, thus requiring a screwdriver to remove valve.