Catalog

4 Way / 3 Position 1/4" NPT Double Solenoid Operated

TECHNICAL DATA:

Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
    22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models)
    45 PSI minimum - Single Solenoid & Single Air Pilot
    45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models)
    Dual pressure applications acceptable when external pilot supply is used.
Flow: Cv 1.1
Temperature Range:
    Solenoid Valve +5ºF to +120ºF
    Air Pilot -20ºF to + 175ºF
    Explosion Proof Solenoid: 0º to +150ºF
Media: Air (either lubricated or non-lubricated)
Seals: Buna-N
Manual Override: Locking

All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory.
Unit of Measure

Specifications

Old Part #

N/A PS 032010-1515 PS 32010-1515 PS-032010-01515 PS032010-1515 PS32010-1515

Coil Voltage

N/A 110V-50Hz/120V-60Hz

Center

N/A Closed

Port Size

N/A 1/4" NPT

Working Pressure

N/A Vacuum service to 150 PSI

Flow

N/A Cv

Temperature Range (Solenoid Valve)

N/A +5 to +120 ºF

Media

N/A Air (either lubricated or non-lubricated)

Seals

N/A Buna-N

Manual Override

N/A Locking

Electrical Data

Electrical Data

N/A
Standard Voltage
(all coils are rated for continues duty)
Power Consumption
Inrush Holding
110 VAC 50 Hz/120 VAC 60 Hz
24 VAC 50/60 Hz
6.4 VA 3.7 VA
12, 24 VDC 2.7 W

Voltage Tolerance: ±10%
NOTE: Electrical connectors must be ordered separately.
One per solenoid required, see Solenoid Connectors page.

Features

Features

N/A
  • The 1/4" 4-way, 5-ported CD07 Valve is an extremely versatile, yet compact, design. This low-profile spool type design will not only enhance the appearance of your equipment, but will save valuable engineering space. A new simplified internal design allows for consistently reliable performance and ease of operation.

  • The CD07 Valve is available with a wide range of solenoid, air pilot and mechanical operators. This new design allows each valve body to be readily STACKED through a convenient and simplified single pressure port bar. Unique optional solenoid connectors offer neon indicator lights for (AC) circuits and L.E.D. displays for (DC) circuits.

  • Standard Plug-In DIN Connection "Low wattage" (2.1W) solenoid and connector, available with or without built-in indicator light.

  • External Pilot: (not shown) Allows an independent air supply to be connected to the pilot port of the solenoid operator.

  • Manual Locking Overrides: Allow supplementary manual control and permit operating the valve when the electric power is off.

  • Solenoid Coil Removal: Un-screw coil retaining nut and slip off the coil.

  • Seal Spacers: New lightweight acetal cartridge assembly.

  • Manifold System: Common pressure port bar

Back To Top