Item # R432013811, Rexroth Series 740 Manifolds and Gang Stacking



4 Way / 2 and 3 Position Manifold Mounts & Gang Stacking

TECHNICAL DATA:

Port Sizes:
    Integrated Fittings for 3/8", 5/16", and 8mm tubing
    Push-in fitting styles bodies available for metric tubing only (2 position only)
Working Pressure:
    20 PSI minimum
    150 PSI maximum
    External Pilots not available
Flow:
    Cv=0.7 - with Integrated Fittings
    (Cv=1.3 - comparable flow to threaded part valve)
Temperature Range:
    Solenoid Valve +5°F to 122°F
    Air Pilot +5°F to 140°F
Media: Air (either lubricated or non-lubricated)
Materials: Polyacetal Engineering plastic with Buna N seals and diaphragms
Combination Manual Override: Locking & Non-Locking

Electrical connectors must be ordered separately. One per solenoid required. See complete listing on Solenoid Connectors page.

Recommended Tubing:
  • Standard 3/8" O.D> x 0.062" wall - poly tubing
    5/16" O.D. x 0.040 wall - nylon tubing
    8mm x 1.00mm wall poly tubing
Requires optional tube nut kit (R432015289)
Valves designed for 10mm O.D. x 1mm wall poly tubing are also available.
Adapters available: 1/4" O.D. x 0.040 wall - poly tubing.
Tube nuts are supplied with each valve for 3/8" x 0.062 wall poly tubing.

SHEAR PLUG KNOCKOUT
Ganged assembly-common supply pressure obtainable by knockout shear plugs.

Stack can be held together and mounted with readily available 1/8" "all thread" material.

MANIFOLD INSTALLATION NOTE:

The first and last segment should always be securely mounted to a plate. If more than five valves are used, every third valve segment should also be securely mounted.

Ordering Example
(4 Station Manifold)
1 - Inlet Segment
1 - End Segment
2 - Station Segment





Specifications  · Electrical Data  · Features

Specifications

Old Part #

P -067701-00000

Description

Inlet Segment

Voltage Tolerance

± 10%

Min. Working Pressure

20 psi

Maximum Working Pressure

150 psi

Temperature Range

+5 to 122 ºF

Media

Air (either lubricated or non-lubricated)

Material

Polyacetal Engineering plastic with Buna N seals and diaphragms

Combination Manual Override

Locking & Non-Locking

Note

  • NEMA 4 Electrical protection
  • UL recognized & CSA approved coils version available
  • Packaged as a cylinder/valve combination with TaskMaster® cylinders sizes 1 1/2" thru 4". See catalog SC-200.
  • Integrated fittings
  • Adjustable built-in flo


Electrical Data
Standard Voltage (all coils are rated for continuous duty) Power Consumption
Inrush Holding
24 VAC-50/60 Hz,
110V-50 Hz/120V-60 Hz
220V-50 Hz/240V
6.4 VA 3.7 VA
6, 12, 24 VDC 2.7 W




Features
Yellow lock tab on manifold segments are scored. This allows the end to be broken off (if desired), making it, tamper resistant, thus requiring a screwdriver to remove valve.



 MORE IMAGES 

·  Manifolds - Outline Dimensions

·  Manifolds Dimensions Data



 Solenoid Connectors 


Rexroth Solenoid Connectors and Cables (8941000302)
8941000302
Aventics Solenoid Connectors and Cables


Rexroth Solenoid Connectors and Cables (R432013747)
R432013747
Aventics Solenoid Connectors and Cables

more available ..


Site created by ThomasNet Web Solutions and powered by Navigator Platform