Catalog

4 Way / 2 & 3 Position 1/4" - 1-1/4" NPTF Solenoid, Air Pilot & Mechanical Operators

TECHNICAL DATA:
Port Sizes: 1/4", 3/8", 1/2", 3/4", 1", 1-1/4" NPTF
Working Pressure:
    Maximum valve inlet air pressure: 150 psi (10.3 bar)
    Minimum air pilot pressure: 15 psi (1.0 bar) w/o return spring (all sizes)
    30 psi (2.1 bar) 1" and 1-1/4" valves w/return spring
    40 psi (2.8 bar) 1/2" and 3/4" valves w/return spring
    50 psi (3.4 bar) 1/4" and 3/8" valves w/return spring
    Valves can also be used for vacuum or dual pressure service when externally piloted.
Flow:
    Cv 2.39 (2390 Nl/min) 1/4" NPTF
    Cv 3.73 (3730 Nl/min) 3/8" NPTF
    Cv 6.17 (6170 Nl/min) 1/2" NPTF
    Cv 7.88 (7880 Nl/min) 3/4" NPTF
    Cv 13.61 (13,610 Nl/min) 1" NPTF
    Cv 15.75 (15,750 Nl/min) 1-1/4" NPTF
Temperature Range: -20ºF to +160ºF (-29ºC to 71ºC)
Media: Air and inert gases (In service higher than 18 cycles per minute or with continuous air flow, a lubricator is recommended.)
Materials:
    Bodies and operators: Die cast aluminum
    Spool: Machined from high-tensile aluminum, hard anodized, ground & polished to 8 micro-inch finish
    Seals: Buna-N, oil-resistant, and bonded to a metallic ring (Hl-Nitrile Buna-N seals are also available.
Manual Override: Non-Locking

Note: Other coil voltages are available - selection will be done at checkout.
Unit of Measure
Items
Aventics PowerMaster® Single Solenoid Valves (4 Way, 2 Position - 1/4" - 3/4" NPTF)

Rexroth PowerMaster® Single Solenoid Tapped Exhaust Valves (1" & 1-1/4" NPTF)

Aventics PowerMaster® Single Solenoid Valves (4 Way, 2 Position - 1/4" - 3/4" NPTF)

Rexroth PowerMaster® Single Solenoid Tapped Exhaust Valves (1" & 1-1/4" NPTF)
Model No. N/A PT 084106-3100 PT 84106-3100 PT-084106-03100 PT084106-3100 PT84106-3100 N/A PT 094106-3100 PT 94106-3100 PT-094106-03100 PT094106-3100 PT94106-3100
Port Size N/A 1 in. N/A 1-1/4 in.
Approx. Weight N/A 10 lb4.5 kg
A N/A 11 1/2 in.
B N/A 13.44 in.341 mm
C N/A 4.13 in.105 mm
D N/A 2.59 in.66 mm
E N/A 4.38 in.111 mm
F N/A 4.19 in.106 mm
G N/A 4.00 in.102 mm
H N/A 1.31 in.33 mm
J N/A 2.69 in.68 mm
K N/A 2.63 in.67 mm
L N/A 2.75 in.70 mm
M N/A 2.13 in.54 mm
N N/A 1.31 in.33 mm
O N/A 1.50 in.38 mm
P N/A 0.34 in.8.7 mm
Q N/A 0.63 in.15.9 mm
R N/A 3.00 in.76 mm
S N/A 2.06 in.52 mm
T N/A 2.19 in.56 mm
Coil Voltage N/A 24 VDC 120 VAC (Standard)
Electrical Data N/A
Standard Voltage
(all coils are rated for continues duty)
Power Consumption
Inrush Holding
120, 240 VAC 60 Hz 33 VA 22 VA
12, 24 VDC 12 W
Features N/A
  • Response time. Actual test data shows only 175 milliseconds is required to fill a 250 cubic inch volume to 80% of line pressure with a normally closed solenoid operated valve. Where a spring is used to open the valve (normally open valve) only 253 milliseconds is required to fill the same volume.
  • Continuous-duty solenoid. Won’t burn out...even when energized for extended periods. Pilot operated for fast response.
  • Lightweight aluminum spool of extra large diameter assures high-speed performance. Requires only short movement to deliver high-capacity air flow. File-hard anodized surface, polished to an 8 micro-inch finish, withstands wear and abrasion; offers greatest sealing qualities, minimum friction and maximum speed. Spool is balanced so air pressure won’t affect its position.
  • Low-friction, positive sealing ring is actually two seals in one; an outer static seal and an inner dynamic seal bonded to a metallic spacer ring. The ring protects the inner seal from the radical compression absorbed by the other seal. Assures longest life with positive sealing.
  • Seal retainers keep inner and outer sealing surfaces in precise position for maximum reliability and efficiency. Combined with the non-compressible seal rings, Power- Master valve retainers eliminate tolerance build-up in the free stack height of both retainers and seals.
  • Free-floating piston with extra large surface area means faster response at lower pressures.
  • Manual non-locking overrides allow supplementary manual control an permits operating the valve when the electric power is off.
  • External pilot allows an independent air supply to be connected to the pilot port in the valve operator or subplate for air pilot pressure.
  • Wire leads of 24" allows simplified conduit wiring.
  • Solenoid coil removal. Unscrew hex nut and slip off the solenoid housing and coil.
  • Exhaust restrictors can be used in either or both exhaust port to provide speed control of cylinders. (Refer to Accessory Valve catalog SC-400.)

Back To Top